Carbon / Water Analyzer CW-800

Carbon / Water Analyzer CW-800

Eltra | Chemical Identification

Determination of released carbon dioxide and water is a special requirement for quality control in the cement and lime industry. ELTRA’s CW-800 analyzer is designed for the precise, simultaneous determination of carbon dioxide and water in lime, gypsum and cement from trace level up to 100 % (depending on sample weight). Other sample materials include ores, soil and minerals. 

The CW-800 is equipped with a resistance furnace with quartz tube for sample oxidation and can provide temperatures up to 1000 °C. The temperature of the CW-800 can be set up in steps of 1 °C and the temperature is fixed during measurement. As common carrier gas in the CW-800 nitrogen is used. 

The detection system of ELTRA’s CW-800 is very sensitive, reliable and guarantees a long lifetime. It can be customized according to the user’s requirements. Two infrared cells can be combined independently and allow highly precise measurement of CO2 and H2O.

Product Advantages

  • simultaneous carbon dioxide and water determination with minimal sample preparation
  • rapid, precise, accurate and reliable element determination
  • wide range of materials can be analyzed
  • resistance furnace temperature can be set up to 1000 °C in steps of 1° C
  • customized infrared cells provide wide, dynamic measuring range
  • due to gold IR path, increased cell live time for analysis of halogen or acid containig samples
  • powerful software (multilingual, customized display, export of results)
  • single and multipoint calibration
  • no halogen trap required
  • electronic gas flow control
  • low maintenance
  • robust design allows usage in production control and laboratory

Features

Measured elements: Carbon dioxide, water
Furnace alignment: horizontal
Sample carrier: quartz boats
Fields of application: construction materials, environment / recycling, geology / mining
Furnace: resistance furnace with quartz tube, adjustable up to 1000 °C
Process of measurement: fixed temperature, fixed carrier gas, no changing during measurement
Detection method: solid state infrared absorption
Number of IR cells: 1 - 2
Material of IR path: gold
Typical analysis time: 2 - 3 min
Chemicals required: magnesium perchlorate, sodium hydroxide
Gas required: nitrogen 99.995 % pure (2 - 4 bar / 30 - 60 psi)
Power requirements: 230 V, 50/60 Hz, max. 10 A, 2300 W
Dimensions (W x H x D): 55 x 80 x 60 cm
Weight: ~ 65 kg
Required equipment: balance (resolution 0.0001g), monitor, PC
Optional accessories: voltage stabilizer 5 KVA

 

Data Sheet

Contact us for pricing