Call Today 1-800-661-6700

Sample Preparation - Inorganic Products

We offer a vast range of premium sample preparation instruments including:

Crushers and Cutting equipment, Grinding and Homogenizing equipment, Mixing and Milling equipment with Cryogenic options, and Pulverizers.

Distillation instruments for Cyanide, Nitrogen, Sulfides, Kjeldahl Digestion Systems.

Also available are systems for Microwave based Digestion.

A wide range of methods comply with AOAC , ISO, USP 233, USP 2232 and EPA methods 3015A, 3051A, 3052 along with 3546. As well, ASTM E1645-01, ASTM D5513-99, ASTM D4309-96 and ASTM E1741-00.

Rapid Cooling Ovens

Rapid Cooling Ovens

Carbolite | Sample Preparation - Inorganic

Rapid cooling ovens are frequently used for annealing thermo-luminescent dosimeters (TLD) that have been used to measure exposure to ionising radiation. The TLD ovens are designed to heat to 400 °C, cooling rapidly to ambient temperatu…

Rotating Tube Divider PT 200

Rotating Tube Divider PT 200

Retsch | Sample Preparation - Inorganic

A faultless and comparable analysis is closely linked to accurate sample handling. Only a sample representative of the initial material can provide meaningful analysis results. Rotary tube dividers ensure the representativeness of a sample…

Rotor Beater Mill SR 300

Rotor Beater Mill SR 300

Retsch | Sample Preparation - Inorganic

The Rotor Beater Mill SR 300 is suitable for coarse and fine size reduction, either in batches or continuously. It can process dry, soft, medium-hard, organic and inorganic substances. Its high speed in comparison to the SR 200 allows a si…

RT 6.5 - RT 75 Sample Splitters

RT 6.5 - RT 75 Sample Splitters

Retsch | Sample Preparation - Inorganic

A faultless and comparable analysis is closely linked to an accurate sample handling. Only a sample representative of the initial material can provide meaningful analysis results. Sample splitters ensure the representativeness of a sample a…

Sample Divider PT 100

Sample Divider PT 100

Retsch | Sample Preparation - Inorganic

A faultless and comparable analysis is closely linked to accurate sample handling. Only a sample representative of the initial material can provide meaningful analysis results. Rotating dividers ensure the representativeness of a sample and…

Shatterbox 8530, Enclosed (SM-200)

Shatterbox 8530, Enclosed (SM-200)

SPEX SamplePrep | Sample Preparation - Inorganic, Spectroscopy

The Shatterbox 8530 (SM-200) Ring & Puck mill with sound-proof enclosure that accommodates sample sizes ranging from 2 - 100 grams. Ideal for pulverizing dry, brittle samples and slurry grinding. CE Approved. Key Features and Specifica…

synthWAVE Single Reaction Chamber microwave synthesis system

synthWAVE Single Reaction Chamber microwave synthesis system

Milestone Inc | Sample Preparation - Inorganic, Sample Preparation - Organic

The new Milestone synthWAVE is designed for safe,reliable and reproducible scale-up of microwaveenhancedchemical reactions.It handles single or multiple reactions at temperaturesup to 300 °C and pressures to 199 bar.Small-scale synthesi…

Tap Sieve Shaker AS 200

Tap Sieve Shaker AS 200

Retsch | Sample Preparation - Inorganic, Particle Size Analysis

The analytical sieve shaker AS 200 tap is used in research & development, quality control of raw materials, interim and finished products as well as in production monitoring. Its tapping motion supports the sieve analysis of certain pr…

TF Tube Furnace Range

TF Tube Furnace Range

Carbolite | Sample Preparation - Inorganic

Carbolite Gero’s versatile new TF tube furnace range incorporates high-quality heating elements and innovative thermal insulation design to achieve first class performance while maintaining both reduced case temperatures and power con…

TG 200 Fluid Bed Dryer

TG 200 Fluid Bed Dryer

Retsch | Sample Preparation - Inorganic

To grind moist or even wet sample materials is not possible without bothersome side effects, especially in jaw crushers, rotor or disc mills. Moist materials tend to block the ring and bottom sieves which can lead to a blockage of the machi…